Software needed to program an S7-1200 PLC
Short answer
TIA Portal with STEP 7 Basic is the only engineering environment for an S7-1200, and the manufacturer's 21-day full trial covers a first troubleshooting visit. The release follows the CPU and the existing project, and the panel model on the machine decides whether a WinCC engineering package joins the install.
On this page
- What software do you need to program an S7-1200?
- Which TIA Portal release does your S7-1200 need?
- Is STEP 7 Basic enough, or do you need Professional?
- Does the HMI on the machine change what you install?
- Can the version you install open the existing project?
- Is the trial long enough for the job?
- Which combination do you install for your machine?
- Questions asked
TIA Portal with STEP 7 Basic is the only engineering environment that programs an S7-1200, so the package itself is not in question; the decisions are the release, the edition and the HMI part. The release follows the CPU and the project already on the machine, and the panel model decides whether Basic is enough or a WinCC engineering package joins it. A full-function trial from the manufacturer covers a first troubleshooting visit, which answers the licensing question for the first visit. Work through the checks below in the order you meet them on site; the last section commits one install combination to each situation.
What software do you need to program an S7-1200? #
TIA Portal with its STEP 7 Basic edition is the only engineering environment that programs the S7-1200, and one installed package carries configuration, ladder and structured text programming, downloads and diagnostics for that CPU. TIA Portal is the frame that holds two engineering parts: STEP 7 for the PLC and WinCC for the operator screens, installed together from one setup. Keep both in view even when the first job is PLC-only, because the site also reports HMI faults. If the naming is new to you, what STEP 7 is in a PLC project, and which one you need separates the classic STEP 7 world from TIA Portal; only the TIA Portal branch touches an S7-1200. No free permanent edition of any of it exists: the no-cost route is the manufacturer's own time-limited trial, planned below.
Which TIA Portal release does your S7-1200 need? #
The release follows the CPU on the machine: an S7-1200 G2 needs TIA Portal V20 or later, while a first-generation CPU needs a release that lists its exact firmware, which you confirm before installing anything. Read the CPU's order number and firmware revision from the label or from the controller's diagnostics; the family name S7-1200 alone does not fix the requirement. Siemens documents that TIA Portal V20 and later supports configuration and programming of the S7-1200 G2 CPU and that older releases do not support the G2 family, and no update back-ports it. A release's updates widen its hardware catalog over time, so a current release with its updates is the safe default for a first-generation CPU.
One documented path exists for old projects: to keep using a project that still contains S7-1200 V1.x CPUs, open it in STEP 7 V13 with any update, convert those CPUs to V2.0 or later, and continue in the newer release. Never change CPU firmware just to suit the software on your laptop: on a machine that must run, a firmware change is a separate maintenance decision with its own backup and recovery path, not a licensing shortcut.
Is STEP 7 Basic enough, or do you need Professional? #
For any machine built on an S7-1200, STEP 7 Basic is enough and is the edition to buy: Basic licenses the whole S7-1200 family, while Professional exists for the larger CPUs, such as the S7-1500 and the S7-300 and S7-400 families. Buy Professional only when the same engineering computer must also open projects for those other families, for example a plant where a filler line runs an S7-1500. For a site built entirely on the S7-1200, Professional adds nothing you can use; put the decision effort into the HMI package instead. For the wider question across several controller vendors, which PLC software you actually need to buy walks the same decision.
Does the HMI on the machine change what you install? #
Yes: STEP 7 Basic engineers screens only for the Basic Panel family, so a machine with any other panel family, or with PC-based screens, needs the WinCC engineering package for that target, licensed separately from the PLC editor. Identify the panel's exact model from its label or its start-up information before you buy anything, because the model name settles this question in one read. A KTP700 Basic belongs to the Basic Panel family, so its screens are engineered inside STEP 7 Basic already. For PC-based visualization, the engineering license and the runtime license are two separate items on the list. If your installed TIA Portal shows no HMI option at all, the cause is a missing component, and a walkthrough on installing WinCC Engineering when TIA Portal shows no HMI option covers that install.
Can the version you install open the existing project? #
A newer release opens an older project and converts it, but an older release cannot open a project saved by a newer one, so the version that last saved the project is your minimum release. Find the newest archive first: ask the previous integrator and check any engineering laptop on site. The archive is the editable project — device configuration, program and engineering data — and it is not the same thing as the compiled copy running in the CPU. Because conversion runs one way, keep the original archive untouched and convert a copy for the new release. If no archive exists anywhere, an upload from the CPU recovers useful PLC content, but it does not recover the separate HMI engineering project. For a site with HMI faults, that asymmetry sets the priority: recover and archive everything before anyone edits.
Is the trial long enough for the job? #
The 21-day full trial covers a first troubleshooting visit when you plan about seven working days and activate it the day before you first connect, which leaves 14 days of margin. Worked example, a hypothetical start-up brewery line with one PLC and one panel. Day 1: install the trial and run its update on the engineering computer (1 day). Day 2: first site visit, recording the CPU order number, firmware, panel model and the newest archive location (1 day). Days 3 to 5: upload or convert, then troubleshoot the reported PLC and HMI faults (3 days). Days 6 and 7: edits, download and verification with production (2 days). The plan needs 1 + 1 + 3 + 2 = 7 working days, so the margin is 21 − 7 = 14 days. Two decisions follow. Activate the trial the evening before day 1 rather than the day you download it, since the entitlement runs from activation. And do the recovery work first, because archives, uploads and a documented project state survive the trial whatever you buy afterwards.
Which combination do you install for your machine? #
Read the CPU family, the project version and the panel model, then take the matching row: the table commits one install combination to each situation a start-up site presents.
| Situation on the machine | What you install | The basis |
|---|---|---|
| First visit, nothing purchased yet | The 21-day full trial of TIA Portal and WinCC | Every component for the visit; buy from the facts you gather |
| CPU is an S7-1200 G2 | TIA Portal V20 or later, STEP 7 Basic | Older releases do not support the G2 family |
| First-generation CPU with a Basic Panel | STEP 7 Basic in the newest release you standardize on | Basic covers the CPU and the Basic Panel screens |
| Project still holds S7-1200 V1.x CPUs | STEP 7 V13 with its update first, then the newer release | Convert the CPUs to V2.0 or later, then move on |
| Panel outside the Basic Panel family, or PC screens | STEP 7 Basic plus the WinCC engineering package for that target | Basic's HMI scope stops at Basic Panels |
| Same computer must also engineer S7-1500 or S7-300 CPUs | STEP 7 Professional | Professional covers those families; Basic does not |
The decisions, case by case. Classic S7-1200 with a Basic Panel: install STEP 7 Basic in your standardized release and stop there; that combination covers the PLC and the screens. S7-1200 G2: the same edition at V20 or later. Any other panel family or PC-based screens: STEP 7 Basic for the PLC plus the WinCC engineering package for that exact target, with the runtime license as its own line. No archive anywhere: trial now, with the upload of the PLC content as deliverable one and the HMI re-engineering scoped as deliverable two.
Installed is not connected. Point the engineering environment at the network adapter that reaches the control network and confirm that the discovered CPU and its address belong to the machine in front of you; when the CPU shows link lights yet stays unreachable, S7-1200 shows link lights but TIA Portal cannot connect works through the causes in order.
Questions asked
Is there a free version of STEP 7 for the S7-1200?
No permanent free edition exists. The 21-day trial is the only no-cost route, and it is the full environment with STEP 7 and WinCC for that period. Download it from Siemens directly, never from a mirror site, and treat the expiry date as a project deadline: engineering after it needs a purchased license.
Can the old STEP 7 V5.5 open an S7-1200?
No. STEP 7 V5.5 engineers the S7-300 and S7-400 families, and the S7-1200 has been programmed in TIA Portal from its first firmware, so a V5.5 installation on your laptop helps with this machine in no way. Spend the disk space on the TIA Portal trial and its update instead.
Does the machine keep running when the trial expires?
Yes. Expiry hits the engineering computer only: the compiled program stays in the CPU and the compiled screens stay in the panel, and neither needs an engineering license to keep running. What stops is editing, downloading and project maintenance, so the license purchase belongs in front of the next change, not in front of the next production day.
Do you need a special computer to run TIA Portal?
Each release lists the Windows versions, memory and disk space it supports, and the trial runs on the same computer you will keep for licensed work. Check that list before you install, because a computer below it spends trial days on installation problems instead of on the machine.