RS10L end effector options: analog input or IO-Link

Controllers and I/O Published 7 min read By IMDHMI controls team

Short answer

For a laser distance sensor on an RS10L end effector, the documented analog route is a 1TH analog input board mounted at 1TR inside the controller, eight channels per board and up to two boards, with the sensor cable run outside the arm. The arm-side 1TY extended I/O board is digital-only, and the documentation identifies no IO-Link master or arm passthrough, so an IO-Link-only sensor has no documented connection on this robot.

On this page
  1. The three routes and what the documentation supports
  2. The 1TH analog input board inside the controller
  3. The 1TY extended I/O board is digital only
  4. The IO-Link question at the end effector
  5. Channel count for one laser sensor on one 1TH board
  6. Running the cable and wiring the channel
  7. Verifying the distance value before the robot uses it
  8. The decision for each case
  9. Questions asked

You can land a laser distance signal in an RS10L, and the documented route does not run through the arm. The sensor cable goes outside the arm to a 1TH analog input board mounted at 1TR inside the controller. The arm-side 1TY extended I/O board is digital-only, and the RS10L documentation identifies neither an IO-Link master option nor an analog passthrough through the arm, so an IO-Link-only sensor has no documented connection on this robot. That makes the sensor's output type the first decision: an analog-output laser sensor has a documented home; an IO-Link-only sensor belongs in the cell PLC instead. This article sets out the three routes the documentation supports, works the channel count for one laser sensor, and ends with the decision for each case.

The three routes and what the documentation supports #

The RS10L material for this question identifies three places an end-effector signal can land, and it draws a hard line between them.

Route Documented hardware What it provides Decision it forces
Arm-side extended I/O 1TY board on the 1TK arm ID board Local digital I/O for end-of-arm tooling Discrete tool points only; it cannot read the laser sensor's analog output
Controller analog input 1TH board mounted at 1TR inside the controller 8 analog input channels per board, up to 2 boards The documented landing point for an analog-output sensor
Arm passthrough or on-robot IO-Link No board, port or wiring provision identified Not established by the documentation Do not design around it; plan the external cable route

Everything you order and wire for this job hangs off that third column. The next sections take the rows in order.

The 1TH analog input board inside the controller #

The 1TH board is a separate purchase. It mounts at 1TR inside the controller and carries eight analog input channels, and up to two boards install, for sixteen analog inputs at the documented ceiling. Before ordering, look at what is already fitted, record the occupied channels against the cell I/O list, and land the sensor on a free channel rather than a configured one.

What the documentation in evidence does not give is electrical detail: no input ranges, no terminal assignments, no scaling units, no configuration screens. Read those from the analog input board manual and its wiring diagram for your controller. Do not infer a channel's range from the board name; the match between sensor output and channel input is a data-sheet decision, and it is the one that decides whether the reading means anything.

The 1TY extended I/O board is digital only #

The 1TY extended I/O board mounts to the 1TK arm ID board in the rear arm area, and its documented job is to give end-of-arm tooling local digital I/O. That is the whole job. It does not convert a discrete point into an analog channel, it does not pass conductors through to the controller, and it is not an IO-Link port. Reading extended I/O as passthrough wiring is the expensive misread in this design, because it sends you looking for conductors the documentation never promised.

IO-Link at the end of arm is a working architecture on other cells: masters built compact and light for weight-sensitive tooling read smart sensors and valve manifolds and hand the data to a PLC. IO-Link itself is the point-to-point digital link standardized under IEC 61131-9, and it needs a master port to exist. Nothing in the RS10L documentation in evidence provides one: no master option, no IO-Link pins on the 1TY board, and an analog input channel is not an IO-Link port, so wiring an IO-Link-only sensor to a 1TH channel reads nothing useful.

Where a master does ride on a moving arm elsewhere, the hardware becomes mounting a concentrated mass on a robot arm link and earns a load check against the arm's data before it is bolted on. For this robot, skip that exercise: no documented port means no IO-Link sensor on the end effector. Pick the analog-output variant of the sensor family, or keep the measurement entirely in the cell PLC on a master there.

Channel count for one laser sensor on one 1TH board #

Inputs for the case this article answers:

  • Signals to read: 1 channel, the laser distance sensor's analog output.
  • Board capacity: 8 analog input channels per 1TH board, from the analog input board documentation.
  • Board limit: up to 2 boards at 1TR, same source.
  • Spare allowance: 1 spare channel of the same signal type, held so a failed channel or a late sensor has somewhere to land.

The rule: count the analog signals the tooling will present, add the spare allowance, and compare the total against installed capacity.

The arithmetic:

  • Channels needed now: 1 signal + 1 spare = 2 channels.
  • Capacity of one board: 8 channels, so 2 of 8 are used and 8 − 2 = 6 remain free.
  • Documented ceiling: 2 boards × 8 channels = 16 analog inputs; there is no third board position.

Result: one 1TH board carries the laser sensor with six channels still free. The decision and its threshold: order one board now, order the second only on the day the analog count reaches the one-board capacity, and treat 16 as the end of the road, because analog signals beyond it belong on PLC-side remote I/O.

Running the cable and wiring the channel #

The controller board solves the electrical landing, not the mechanical route. No passthrough through the arm is documented, so the sensor cable runs outside the arm in a dress pack rated for continuous flex, and you put that run on the layout at the start instead of retrofitting it after the arm is commissioned.

Isolate and lock off the controller per your site's electrical work procedure before opening it or working on arm wiring.

  1. Read the laser sensor's data sheet for its output type and range, and the analog board manual for the channel's documented input range. A mismatch reads wrong or dead, the same failure that makes a millivolt sensor read zero on a 0-10 V input.
  2. Confirm which 1TH boards are fitted at 1TR, mark a free channel, and record it against the I/O list.
  3. Route the sensor cable through the dress pack on a path clear of the arm's pinch and wrap points, in cable rated for the arm's continuous flexing.
  4. Land the signal pair and its reference on the selected channel per the board wiring diagram, matching polarity, signal common and shielding to both documents.
  5. Scale the channel so the raw count becomes millimetres. An analog input converts the signal into a number the program scales, the same conversion chain how PLC analog input and output modules convert signals walks through.
  6. Confirm the arm and controller manuals for your exact configuration before altering wiring or adding a board.

Verifying the distance value before the robot uses it #

Prove the chain end to end. Put a target at a known distance, compare the controller's live channel value with the sensor's own indication, then repeat at two more distances across the working range. The value must move in the right direction, hold steady, and scale correctly; a plausible but wrongly scaled channel tracks the target while reporting the wrong distance, which is the failure that survives a bench check and wrecks the process. If the channel sits pegged or noisy, measure the signal at the sensor terminals and at the channel and compare them. If the output is a current loop, a loop simulator proves the input, and it has to sink current to stand in for a two-wire transmitter, as why a loop simulator needs a current sink output explains. Last check: the mapped program variable follows the channel before any motion logic consumes the value.

The decision for each case #

  • Analog-output laser sensor: buy one 1TH board, mount it at 1TR, land the sensor on a free channel, and design the dress pack run in from the first layout. Only a documented internal route in your arm wiring documentation removes the dress pack; nothing else does.
  • IO-Link-only sensor: no documented connection on this robot. Choose the analog-output variant of the sensor, or run a master at the cell PLC and keep the distance in the PLC's program, because the robot has no documented way to read it.
  • Distance value wanted by the line rather than the robot: land the sensor on a multi-channel Modbus analog input remote I/O module in the cell. The RS10L documentation identifies no link between such a module and the robot controller, so the robot program will not see the value.
  • Discrete tooling points: the arm board carries them; confirm the option is present before counting on them.

Questions asked

How do I check that the extended I/O option is installed and enabled?

Look for the 1TY extended I/O board mounted to the 1TK arm ID board. The documented indication that the option is installed and enabled is that Aux Func 0607 is available in the controller. Read that as proof of digital I/O only: it says nothing about analog inputs, which live on the separate 1TH board inside the controller.

Can the digital tooling points and the analog sensor share one board?

No. The 1TY board on the arm carries the discrete end-of-arm tooling signals and the 1TH board inside the controller reads the analog signals. They are separate boards in separate places, and neither converts one signal type into the other, so the digital points and the laser sensor's analog output are planned as two independent resources.

What does a PLC-side analog module for this sensor look like?

A typical compact unit of the kind used near the tool offers multi-channel current inputs reading 0 to 20 mA at 12-bit resolution from a 7 to 36 V DC supply. That suits line and inspection logic in the PLC, but the RS10L documentation identifies no connection between such a module and the robot controller, so the robot program does not read it directly.

Does the analog input channel power the laser sensor?

Plan the sensor's supply separately. The documentation in evidence describes the 1TH as an input board and gives no sensor-supply provision for its channels, so power the laser sensor as its own data sheet requires, from the panel or tooling distribution. Keep the supply conductors out of the analog signal pair and land only the signal and its reference on the channel.

Keep reading

  • Explainer

    How PLC analog input and output modules convert signals

    Analog input modules amplify and digitize a field voltage or current into a 12-bit binary code (4,096 counts) or a three-digit BCD value, and the program scales that code into engineering units. Analog outputs run the same path in reverse through a DAC. Troubleshoot in the order signal, format, scaling.

    Controllers and I/O

  • How-to

    How to add a 4-20 mA sensor to a PLC without analog inputs

    Connect the transmitter through a CP1W analog input expansion unit on the CP1E's expansion connector and scale it with Pressure_bar = (I_mA - 4) × (10 bar / 16 mA). If no expansion unit fits, convert the 4-20 mA loop to a 0-1 kHz pulse train with a 24 VDC signal conditioner and count it on a high-speed counter input over a fixed gate.

    Controllers and I/O

  • How-to

    Scale MicroLogix analog inputs to Pascals over DF1 reads

    Stage the analog word into an N7 integer with a MOV and read that register over DF1; the driver does not serve the physical input word. Scale counts to volts linearly, apply the gauge exponent in one place, and check two injected points, because 10 mV of voltage error moves the reading 2 to 4 percent.

    Controllers and I/O