Selection guide

Choosing an S7-1200 starter kit for learning SCL programming

PLC programming Published 8 min read By IMDHMI controls team

Short answer

Learn SCL in PLCSIM first: a simulated S7-1200 runs every exercise in an SCL course book with no hardware attached. If you buy hardware, take a CPU 1212C in the AC/DC/RLY build (order number 6ES7212-1BE40-0XB0) over the CPU 1211C starter kit — the 1211C is closed to signal-module expansion and an HMI adds nothing to SCL practice. Buy a full STEP 7 Basic license when the 21-day trial ends.

On this page
  1. What SCL practice actually needs
  2. Software first: the trial and the license
  3. CPU 1211C starter kit against a CPU 1212C build
  4. Sizing the bench feed for a CPU 1212C at 230 V AC
  5. First wiring and download on real hardware
  6. The SCL-to-LAD loop the interview tests
  7. HMI and PROFINET: postpone both
  8. The decision, case by case
  9. Questions asked

Learn SCL in PLCSIM first: a simulated S7-1200 runs every exercise in an SCL course book — editor, compiler, online monitoring, timers, data blocks — with no hardware at all. Buy hardware only when exercises must touch real wiring, and then take a CPU 1212C build over the CPU 1211C starter kit: order number 6ES7212-1BE40-0XB0, the AC/DC/RLY variant, so the bench runs from a wall socket. The CPU 1211C is closed to signal-module expansion, and an HMI panel adds nothing to SCL practice. Two purchases remain: the CPU and a full STEP 7 Basic license, because the 21-day TIA Portal trial expires and a CPU ships with no right to edit, compile or download a project.

What SCL practice actually needs #

Course-book work asks four things of the toolchain and nothing more: an editor that compiles SCL, an execution target that runs the compiled blocks, online monitoring of the variables, and a repeatable test sequence. Terminal wiring, PROFINET commissioning and operator screens are separate competencies, and no SCL exercise in a course book depends on any of them.

PLCSIM covers that list on a simulated S7-1200. It exposes compile errors, state-machine faults, wrong conditions, data-type mistakes and most sequencing problems, and it shows the same monitored values you would watch online on a real CPU. What it cannot validate is terminal wiring, output loading, device naming and the behaviour of a real network partner. That boundary is the only reason to buy hardware for this course, so the purchase decision reads: license always, CPU only for wiring practice, nothing else.

Software first: the trial and the license #

Settle the software before ordering hardware, because a CPU ships with no right to edit, compile, download or simulate. The kit shown in the trade listings carries the TIA Portal trial, and that period runs 21 days. Plan the whole first pass to land inside it: installation, activation, a project with the exact CPU type configured, the simulated chapters, and — if a CPU is coming — one hardware download and one online session before the clock runs out.

After the trial, the from-zero path is a full STEP 7 Basic license. The same listings show an upgrade part, order number 6ES7822-0AA05-0YE5, beside a full part, 6ES7822-0AE06-0YA5. An upgrade presumes a qualifying earlier license and will not activate as a first license, so the full part is the buy unless you already own the qualifying base. Siemens does not publish a free full edition of TIA Portal, and its own starter-kit brochure documents bundles that include STEP 7 Basic with the CPU — read a kit's content line before paying, because a trial-only bundle and a licensed bundle are easy to confuse.

CPU 1211C starter kit against a CPU 1212C build #

Read the three-part designation as supply, input, output. DC/DC/DC is a 24 V-powered CPU with DC inputs and transistor outputs; AC/DC/RLY is a mains-powered CPU with DC inputs and relay outputs. The kit in the listings carries a CPU 1211C DC/DC/DC plus a pushbutton, which is why that bench also needs a 24 V supply before anything runs.

Memory is not the 1211C's problem: the product brochure puts 50 KB of program memory on it, which a course book fits with room to spare. Expansion is. The CPU 1211C is closed to signal modules, so a bench that should grow dead-ends at its onboard I/O. The SIMATIC S7-1200 system manual (entry ID 109741593) lists the digital, analog and thermocouple and RTD signal modules the family supports; match that list against the exact CPU before ordering anything that plugs in. A CPU 1212C in the AC/DC/RLY build, order number 6ES7212-1BE40-0XB0, keeps the same programming workflow, takes mains directly and leaves the signal-module path open — and Siemens' own kit brochure points the same way, documenting bundles built on a CPU 1212C AC/DC/RLY or a CPU 1212FC DC/DC/RLY rather than on the 1211C.

Bench decision CPU 1211C starter kit CPU 1212C AC/DC/RLY build
Part shown in the listings CPU 1211C DC/DC/DC with a pushbutton 6ES7212-1BE40-0XB0
Program memory 50 KB check the CPU 1212C product data
Signal-module expansion none — closed to signal modules open; match the system manual's module list to the exact CPU
Bench supply a 24 V DC supply is required before anything runs a wall socket, AC input, 47 to 63 Hz
Onboard I/O, AC/DC/RELAY build of this family 6 DI 24 V DC, 4 relay DO at 2 A, 2 AI 0-10 V DC (documented for 6ES7211-1BE40-0XB0) confirm on the CPU 1212C product data
License it carries the 21-day trial check the kit's content line; bundles with STEP 7 Basic exist

Sizing the bench feed for a CPU 1212C at 230 V AC #

The inputs, each with its source:

  • Input current, CPU only, maximum load: 80 mA at 120 V AC and 40 mA at 240 V AC — the CPU 1212C power-supply specification.
  • Permitted line frequency: 47 to 63 Hz, the same specification page.
  • Bench feed: a domestic socket at 230 V AC nominal, the desk setup this bench uses.

The rule in words: the two documented current figures sit at the same apparent power, so the constant-VA step comes from the manufacturer's own data — compute the volt-amperes once, then divide by the bench voltage.

120 V × 0.080 A = 9.6 VA

240 V × 0.040 A = 9.6 VA

9.6 VA ÷ 230 V = 0.0417 A, about 42 mA

The result: at nominal 230 V the CPU alone draws about 42 mA, roughly 10 VA. The decision: the AC-input build needs no bench power supply for the CPU — the wall socket is the supply, and 42 mA is noise to any domestic circuit. A DC/DC/DC build inverts it: its documented CPU-only draw is 400 mA at 24 V DC, so a 24 V supply, once exercises attach real sensors or loads, is sized above 400 mA for the CPU alone.

First wiring and download on real hardware #

  1. Wire the power terminals with the circuit de-energized. The AC builds take mains directly on the CPU — the family's AC/DC/RELAY build is documented at AC 85-264 V AC, on 6ES7211-1BE40-0XB0 — so keep live terminals in an enclosure or behind a shroud; a bare CPU with live screw terminals on a desk is the one real hazard on this bench.
  2. Give the bench one maintained pushbutton on an input and one indicator on an output. The relay-output build switches an isolated load circuit — read the relay contact rating in the product data before switching a mains load. The kit's DC/DC/DC CPU has transistor outputs that take their load voltage from the 24 V bench supply instead.
  3. In TIA Portal, insert the exact CPU type in the device configuration, compile the hardware configuration to zero unresolved errors, and download over the CPU's built-in PROFINET port.
  4. If the CPU stays unreachable, the PC side is the usual cause: TIA Portal needs the PC's IP address set in the project before the S7-1200 answers — Why an S7-1200 is reachable only after TIA Portal adds a PC IP address walks through that fault.
  5. Go online and watch the input bit with nothing forced: it must change only when the physical pushbutton changes, and the indicator must follow the tested logic with no entries waiting in the CPU diagnostic buffer.

The SCL-to-LAD loop the interview tests #

The adverts that ask for SCL name good TIA Portal knowledge beside PROFINET, and the fastest way to show it is the two-language loop: implement each exercise in SCL, compile it clean, then rebuild the same function in LAD and confirm the output sequence survives the language change unchanged.

Give every exercise an acceptance table before coding: initial state, input action, expected output, reset condition. Run normal, boundary and invalid sequences in PLCSIM with the relevant variables watched, then repeat the same table on the CPU once the simulated result is stable. Which language fits which control task is its own decision — Which IEC 61131-3 PLC language to use for each control task sorts that out — and the ladder side has a step-by-step track in How to learn Siemens ladder logic programming step by step.

HMI and PROFINET: postpone both #

An HMI panel adds nothing to SCL practice: no course-book exercise depends on a screen, so it moves budget away from the license without touching the learning goal. Add one when operator-screen work becomes the goal, on a CPU that already runs stable.

PROFINET between controllers needs a second PROFINET device; a single CPU shows the configuration basics but cannot demonstrate cyclic data exchange. Build that protocol practice in simulation first — How to build a virtual PLC test bench for protocol practice sets up exactly that bench — and let it carry the PROFINET configuration and diagnostic drills until a real second device is justified.

The decision, case by case #

  • Course book only: buy nothing yet. PLCSIM inside the trial runs every SCL exercise; buy the full STEP 7 Basic license when the trial ends.
  • Wiring practice plus growth: a CPU 1212C AC/DC/RLY, order number 6ES7212-1BE40-0XB0, plus the full license. It runs from a wall socket and keeps signal modules open. No HMI, no panel, nothing else.
  • The CPU 1211C starter kit: only when the exercise list is fixed and fits its onboard I/O forever — accepted as 50 KB of program memory and zero signal modules, it is a closed bench.
  • HMI and a second PROFINET device: postpone both until the SCL-to-LAD loop runs clean on real hardware.

Questions asked

Can an S7-1200 bench teach PROFIBUS as well as PROFINET?

The onboard port on an S7-1200 CPU is PROFINET only. PROFIBUS on this family needs an added communication module, and the SIMATIC S7-1200 system manual lists which modules each CPU accepts — match that list to your exact CPU before ordering. For the PROFINET skills a job advert names, one real CPU plus a simulated partner covers configuration and diagnostics; PROFIBUS practice needs both the module and a DP-capable device on the bench.

Does classic STEP 7 V5.5 experience count toward a TIA Portal job?

Only partly. The S7-1200 is programmed in TIA Portal alone; classic STEP 7 V5.x does not support it. SCL syntax, data typing and block structure carry over directly, while the project tree, device configuration and diagnostics workflow do not. If an advert names V5.5 with S7-300 or S7-400 hardware, treat that as a second toolchain to learn after the S7-1200 bench runs.

Will the relay outputs on the AC/DC/RLY CPU switch mains loads directly?

They switch an isolated load circuit through relay contacts, so a small indicator load runs straight from the output terminals. The contact rating is per-output product data for the exact order number — read it before attaching any mains load, and keep the switching wiring enclosed. On the kit's DC/DC/DC CPU the outputs are transistor channels, and they take their load voltage from the 24 V bench supply instead.

What fits inside the 21-day TIA Portal trial?

The same installation as the full product, including the PLCSIM simulator, so every simulated exercise in an SCL course book fits inside it: install, activate, configure the exact CPU type, and keep the one hardware download for the end if a CPU is arriving. Once the period expires, editing and downloads stop until a full license is installed, so pace the chapters to finish inside it.

Keep reading

  • Explainer

    Will an S7-200 starter kit teach you S7-300 and S7-400

    Yes for fundamentals, no for the toolchain: an S7-200 starter kit teaches scan-based ladder logic, timers and counters that transfer to S7-300/400 work, but Micro/WIN and STEP 7 are separate tools and no project converts between them. Budget the larger share of practice hours for STEP 7, and buy any S7-200 kit as used training hardware, since new supply ended 1 October 2014.

    PLC programming

  • Selection guide

    Selecting an S7-1215C CPU for Modbus TCP and OPC UA

    Yes, the S7-1215C carries a Modbus TCP client to the subordinate controller and an OPC UA server for the edge gateway, once firmware V4.4 or higher and the SIMATIC OPC UA S7-1200 Basic option (6ES7823-0BA00-2BA0) are on the order; the two PROFINET ports settle wiring, not capacity, and at this scale both protocols together load the port by a hundredth of a percent.

    PLC programming

  • Selection guide

    Software needed to program an S7-1200 PLC

    TIA Portal with STEP 7 Basic is the only engineering environment for an S7-1200, and the manufacturer's 21-day full trial covers a first troubleshooting visit. The release follows the CPU and the existing project, and the panel model on the machine decides whether a WinCC engineering package joins the install.

    PLC programming