Why Telegram 750 torque control on an S7-1200 G2 needs its own example

Drives and motion Published 8 min read

Short answer

Yes: an S7-1200 G2 runs torque control over Telegram 750 to a SINAMICS S200 PN drive, but from the dedicated G2 application example, not from default integration. The note restricts what the engineering environment ships, not what the controller and drive can exchange. A clean compile of TorqueFB_TEL750 proves program structure only; the G2 package supplies the hardware configuration and cyclic process-data mapping to verify against.

On this page
  1. What 'not supported by default' actually restricts
  2. What a clean compile proves, and what it does not
  3. What Telegram 750 carries in this application
  4. What a half-limit command does to a lightly loaded 2.4 N·m axis
  5. The commissioning gates on the G2 project
  6. The decision for each case
  7. Questions asked

Yes, torque control over Telegram 750 runs on a SIMATIC S7-1200 G2 with a SINAMICS S200 PN drive — but you build it from the dedicated application example for exactly that controller-and-drive pair, not by copying the shared project and trusting a clean compile. The note in the shared torque example states that the S7-1200 G2 generation does not support Telegram 750 by default, and it names the G2-specific entry to use instead. By default is the operative phrase: it restricts what the engineering environment ships ready-made, not what the controller and drive can exchange. A clean compile of TorqueFB_TEL750 proves your program is structurally sound; it proves nothing about the hardware configuration and cyclic process-data mapping that reach the drive. This article separates the two claims and ends with the decision for each case.

What 'not supported by default' actually restricts #

Default support and application-example support are different claims, and the note only makes the first one. Default support means the engineering environment ships the integration directly: you select the telegram for the drive in the project and the tooling configures the exchange for you. An application example is a maintained package that supplies the additional configuration and program logic the default path does not. The note in the shared application, entry 109821017 (SINAMICS S200 PN: Torque application via Telegram 750), says the new S7-1200 G2 generation does not yet support Telegram 750 by default and points to entry 109988351 for the G2 controller with the S200 — a statement about packaging, not about whether the function can run.

The distinction is easy to miss because the two packages overlap on the surface: the G2-specific application uses the same block, TorqueFB_TEL750, and it compiles without error. A function block is a reusable program component with its own instance data, and its name identifies neither the supported controller configuration nor the telegram mapping behind it. The drive side is not the question either: the S200 PN drive system supports the supplementary Telegram 750, described in its documentation as carrying the additional torque setpoint and an upper torque limit over the drive's PROFIdrive process-data interface. So the honest reading of the note is this: with the G2 package as the baseline, torque control over Telegram 750 on this pair is a supported engineering path; without it, you are assembling the integration yourself and carrying the verification burden alone.

What a clean compile proves, and what it does not #

A compile checks program structure, data types, referenced objects and configuration consistency inside your project. It does not demonstrate that the physical drive receives the intended process data or responds correctly to a torque demand, and the same block can compile in two projects whose hardware configuration, cyclic data mapping or execution conditions differ. Treat compiler acceptance as one commissioning gate, not as a compatibility certificate. The gates after it are the same ones you would run when troubleshooting S7-1200 PROFINET servo motion control issues on any drive.

Observation What it demonstrates The check it does not replace
TorqueFB_TEL750 compiles The block is accepted in the configured project Hardware and software versions against the G2 package requirements
Controller and drive exchange cyclically The PROFINET connection operates Telegram layout and process-data interpretation at both ends
The drive reports ready Its documented readiness conditions are met Operating mode, command acceptance and torque limits
A torque demand moves the axis The command path has an effect Direction, scaling, limiting and stopping behavior

Compile hardware and software together after any device-selection or migration issue, and clear the warnings that touch device versions, addresses or block connections before you download. A clean download is the second gate; the rest of the table is runtime work, and none of it can be signed off from the compiler.

What Telegram 750 carries in this application #

A telegram is the cyclic process-data arrangement a controller and a drive exchange every bus cycle, and both ends must agree on order, length, data type and scaling; an online connection can look healthy while one word is read wrongly. For this drive, the application documentation describes Telegram 750 as a supplementary telegram that adds the torque setpoint and an upper torque limit to the cyclic exchange, so the controller commands torque and bounds it every bus cycle instead of editing drive parameters between them.

Keep the telegram arrangement the G2 example supplies unless its documentation calls for a change. Selecting a telegram in the hardware configuration and calling a block with a matching name are separate actions; neither one checks the block's connections for you. Trace every process-data connection TorqueFB_TEL750 uses through the configured I/O assignment and compare it with the drive-side telegram, field by field, for overlap and offset. That is the same discipline behind cyclic telegram data for a PROFINET servo drive in general: the layout only works when both ends interpret it identically.

What a half-limit command does to a lightly loaded 2.4 N·m axis #

Worked example, with illustrative inputs for a typical small servo axis — not values from the application package: a motor with a rated torque of 2.4 N·m, a torque command at half the rated value, a total inertia of 0.003 kg·m² referred to the motor shaft (rotor plus reflected load), a rated speed of 3000 rpm, and friction and opposing load treated as negligible. Substitute your own drive's rated torque, your inertia figure and your motor's rated speed.

In torque mode the drive regulates torque, not speed or position, so with nothing opposing it the whole command accelerates the axis: acceleration equals torque divided by inertia.

  • Command: 2.4 N·m × 0.5 = 1.2 N·m at the motor shaft.
  • Acceleration: 1.2 N·m ÷ 0.003 kg·m² = 400 rad/s².
  • Rated speed: 3000 rev/min × 6.2832 rad/rev ÷ 60 s/min = 314.16 rad/s.
  • Time to rated speed: 314.16 rad/s ÷ 400 rad/s² = 0.79 s.

An unopposed half-limit command carries this axis from standstill past rated speed 0.79 s after enable — faster than an operator can reach a stop, and on a bench with the coupling open that is a runaway, not a commissioning step. The value that bounds it is the upper torque limit the telegram carries each cycle.

The input that moves the result most is inertia: time equals speed times inertia divided by torque, so doubling the referred inertia to 0.006 kg·m² doubles the time to about 1.6 s, and doubling the command halves it.

Run this arithmetic on your own numbers before the first enable. If your time to rated speed lands under a second, as the 0.79 s here does, treat an unopposed enable as a runaway: couple the load, lower the limit or both, until your computed time is long enough for your stopping method to act — and prove zero demand at the drive before the first enable, because a scaling or sign error turns the upper torque limit into the only thing standing between the axis and full torque.

The commissioning gates on the G2 project #

Run the gates in order on the G2 package rather than on your own reconstruction:

  1. Download the G2-specific application and its documentation from the Siemens support portal, and read the requirements list before opening the project.
  2. Compare the installed controller generation, drive, engineering software and firmware against that list. The shared package's requirements do not transfer; each package stands on its own.
  3. Compile hardware and software together in the G2 project, clear device-selection and migration errors, then resolve the warnings that touch device versions, addresses or block connections before downloading.
  4. Trace every process-data connection the torque block uses through the I/O assignment and compare controller-side and drive-side telegram settings for order, length and type.
  5. Go online with motion inhibited by your commissioning arrangement and confirm the cyclic connection is established without communication faults; compare the application's readiness indication with the drive's own diagnostics.
  6. Verify the command representation before the first enable: the unit, sign convention, reference quantity and conversion the application documents, and zero demand transmitting as zero.
  7. Check the drive's configured torque and speed limits against the motor and the machine, then size the first motion test with the arithmetic from the worked example above.

A proven cyclic path is not a tuned axis. Once the path works, the drive's loop gains decide how the axis actually responds, and they differ from machine to machine and axis to axis — the subject of why the KV factor varies from 0.6 to 3.7 because axis loop tuning differs.

The decision for each case #

Starting torque control on an S7-1200 G2 with a SINAMICS S200 PN drive: build from the G2-specific application, entry 109988351. The combination is usable, and the note is steering you to the package that carries the integration; take its hardware configuration, telegram mapping and program structure as the baseline and adapt from there.

Already copied TorqueFB_TEL750 into your own G2 project and it compiles: keep the compile as a gate you have passed, nothing more. Move your logic onto the G2 package's hardware configuration and cyclic mapping, because the block alone does not carry them, and rerun the runtime gates before enabling torque.

On a classic S7-1200 or an S7-1500: the G2 note does not apply to your controller. The shared application, entry 109821017, is the documented baseline for that torque application, and the same compile-versus-runtime discipline still decides when you can enable.

The note and the clean compile bar were never in conflict. One says what ships by default; the other says your program is well-formed. The G2 package is what makes the hardware, the telegram and the program agree — and enabling torque waits until the runtime gates say so, not until the compiler does.

Questions asked

Does the default-support note mean an S7-1200 G2 cannot do torque control with a SINAMICS S200?

No. The note says the engineering environment does not ship Telegram 750 integration for that controller generation directly, so the standard telegram selection path in the project does not offer it. The dedicated application example for the S7-1200 G2 and SINAMICS S200 supplies the configuration and program that the default path leaves out, and that package documents the intended combination. The restriction concerns packaging, not the drive's telegram capability or the controller's cyclic exchange.

Can I keep my own G2 project and only copy the torque block into it?

It may compile, but the block does not carry the hardware configuration or the cyclic process-data mapping, so a copied block alone leaves the integration unverified. Start from the G2 package instead, move your logic onto its configuration, and keep the documented calling arrangement for the first commissioning test. Change one interface at a time after the supplied arrangement works, so an integration fault stays distinguishable from a drive fault.

How do I know what the torque command value means before enabling?

Read the command representation from the application documentation and the drive configuration, and record four things: the unit, the sign convention, the reference quantity and the conversion between engineering units and the transmitted value. A number on your screen is not automatically a torque in newton metres. Apply the same check to the torque feedback so demand and actual can be compared, and confirm zero demand transmits as zero.

What happens if my controller or drive firmware does not match the package requirements?

The package is verified for exactly the versions its requirements list, so anything outside that list is untested by it, not automatically wrong. Check whether the telegram support in your drive firmware is documented, and treat the first run on mismatched versions as a validation test: compile clean, check the cyclic mapping word by word, and enable torque first with the load coupled and the stopping method proven.

Keep reading

  • Troubleshooting

    Troubleshooting S7-1200 PROFINET servo motion control issues

    Fix an S7-1200 PROFINET servo project in order: compile the motion calls in FB1 first, set drive and TIA Portal to the same telegram — Telegram 3 on this pairing — then prove one axis holds enable and velocity through repeated scans. A first-generation CPU 1214C executes independent single-axis motion only; the flying shear's deterministic master-slave cut belongs in the drives or in a motion-class controller, and no telegram adds it.

    Drives and motion

  • Explainer

    What you need before requesting an X20 ACOPOS machine program

    No one can hand you a machine program from an X20 CP1584 and ACOPOS 1090 model list: the sequence, I/O assignment, drive configuration, motor data, safety requirements and motion profile are the program, and only the machine's builder or developer holds them. Request the source project with the Automation Studio build it was saved with, and treat the installed motion samples as a study baseline only.

    Drives and motion

  • How-to

    How to run CiA402 axes in structured text without NC

    You can move EtherCAT servo axes from a PLC without a motion-control license by writing the CiA 402 state machine and the move profiles in plain structured text that maps the drive PDOs directly: one function block per axis, one command owner per axis, every transition gated on the returned status word. Commission the five hops from application to drive with a gate check each, and prove task timing under full load before enabling torque.

    Drives and motion