Short answer

Match the machine to the family by scope: the SS2 is the fast 14-point base for small standalone stations, the ES2 line is the default for mainstream machines, SA2 and SX2 buy performance and high-speed headroom, and the SV2 is the integrated-motion family — any servo or stepper axis under PLC control lands there. Replace installed units like-for-like, and pull exact point counts, program capacity and module support from Delta's current catalog before ordering.

On this page
  1. The families and what the line contains
  2. Match the family to the machine
  3. DVP family comparison
  4. Worked example: an 18-point transfer station
  5. Communications and SCADA
  6. New design or installed base
  7. Before you order
  8. Questions asked

Choose the DVP family by the machine's scope, then confirm the model's numbers in Delta's current catalog. The SS2 is the fast second-generation small base with 14 I/O points; the ES2 line is the default for most standalone machines; the SA2 and SX2 buy performance and high-speed headroom up the slim line; and the SV2 is the integrated-motion family — any servo or stepper axis under PLC control lands there. A machine already running a first-generation SS, SA, SX, SC or SV gets a like-for-like replacement, not a redesign. Below are the decision table, a worked sizing example and the short list of numbers to pull before the order.

The families and what the line contains #

Delta's DVP range is one controller line with two slim generations plus models above them. The current catalog lists the first generation — SS, SA, SX, SC and SV — beside the second — SS2, SA2, SX2 and SV2 — along with the ES2, EX2, EH3 and SE models. On the SS2, the step from SS is documented as faster execution and enhanced monitoring; that improvement is what the 2 buys, and it is why new designs start on the current generation.

The ES2, EX2, SS2, SA2, SX2 and SE models share one operation manual, so the mainstream line runs one instruction set and one programming model. For selection that means moving a station up a family is a re-sizing exercise, not a retraining exercise.

Match the family to the machine #

Work the rules in this order and stop at the first one that fits:

  • Count the I/O the machine needs today, inputs plus outputs, and multiply by 1.2. A new machine carries at least 20% spare I/O; a base at 100% utilization is a change order waiting for wiring.
  • Eleven machine points or fewer — 14 ÷ 1.2 = 11.67 — take the SS2 and its 14 points.
  • One controller, discrete machine, more points than that: take an ES2-family base at the smallest point count at or above your spare-adjusted total, with the base sizes taken from the model's catalog line.
  • Program size, scan demand or communications sessions beyond the mainstream base: the SA2.
  • High-speed counting, dense analog mixes or point-to-point moves short of coordinated motion: the SX2.
  • Any axis under PLC control: the SV2. Positioning, speed control and synchronization are that family's job, whatever the I/O count says.
  • A station that outgrows the slim line entirely: the EH3 and SE models above it.

One boundary no family choice crosses: a DVP controller is a standard controller, not a safety controller — a stop function with a required SIL or PL belongs in a safety relay or safety controller wired and validated for that function, never in DVP ladder alone.

DVP family comparison #

Family Slot in the line Pick it when Pass it when
DVP-SS2 Second-generation small base; 14 I/O points; faster execution than the SS it replaces The machine fits 11 points with the 20% spare rule The point count, analog or motion exceeds it
DVP-ES2 / EX2 Mainstream compact bases with integrated I/O and communication ports Most single-controller machines — the default Coordinated or multi-axis motion is required
DVP-SA2 Higher tier of the slim line: more performance, memory and networking than the mainstream base Bigger programs, faster scan, heavier communications load The job fits the ES2 base without strain
DVP-SX2 The tier above SA2, with high-speed I/O and analog headroom Fast counting, analog-heavy mixes, simple moves Axes need coordinated motion — go SV2
DVP-SV2 The integrated-motion family Positioning, speed control, synchronization The machine has no servo or stepper axes
DVP-EH3 / SE The models above the slim line The station outgrows slim bases A slim base still carries the station

First-generation SS, SA, SX, SC and SV models stay in the catalog for installed-base spares; they are not the pick for a new machine.

Worked example: an 18-point transfer station #

A pallet transfer needs 11 inputs — photoelectric sensors, limit switches and one E-stop monitored-contact feedback — and 7 outputs: solenoid valves, contactors and a stack light.

  • Machine I/O: 11 + 7 = 18 points.
  • Spare-adjusted requirement: 18 × 1.2 = 21.6, so the base must carry at least 22 points.
  • SS2 check: 14 points against a 22-point requirement is short by 8, before any growth. The SS2 is out.
  • Decision: an ES2-family base at the smallest documented point count at or above 22.

Change the machine to 8 inputs and 4 outputs instead: 12 points, 12 × 1.2 = 14.4, so 15 points needed, and the SS2's 14 misses by one. Two right answers: the smallest ES2 base, or the SS2 with one extension module when the enclosure must stay small — the module path is part of the slim line's documented build, and the module count the 14-point base drives is the one number left to verify.

Add two servo axes feeding the transfer and the family decision changes while the arithmetic barely does: axes under PLC control put the station on the SV2 whatever the point count says.

Communications and SCADA #

Between controllers, the documented native link is Modbus RTU over RS-485: an RS-485 Modbus RTU setup between an ES2 and an SS2 covers the wiring and register mapping end to end. Up toward the plant, pick the protocol before the hardware — How to choose between Modbus, Profibus and CANopen settles that by application — then confirm which communication module the chosen base accepts. On the software side, Selecting SCADA software for mixed PLCs and SQL logging picks up where the controller choice ends.

New design or installed base #

The catalog still lists the first slim generation beside the current one, so the two jobs get different answers. New machine: always the 2-series — the documented SS2-over-SS gain in execution speed and monitoring is what you are buying, and the same reasoning carries SA2 over SA and SV2 over SV. Installed panel needing a spare: same generation, same model, like-for-like; redesigning the controller during a repair adds commissioning risk the machine never asked for.

Before you order #

  • Base points at least 1.2 × today's I/O count; write the arithmetic on the drawing.
  • Analog points and their signal types — in the base or in an extension module.
  • Any axis: SV2, with the axis and pulse-channel counts from the model's own line.
  • The protocol the drives, SCADA or peer controllers speak, and the communication module that base accepts.
  • 24 V DC budget: sum the current consumption of the base and every extension module from the operation manual's tables, then size the supply above the sum.
  • Program capacity in steps for the exact model, and confirmation that the model sits in the current catalog rather than a discontinued list.

Questions asked

Can the 14-point SS2 be expanded?

Yes — extension modules are part of the documented build for the slim line: the operation manual covering the ES2, SS2, SA2 and SX2 models lists current-consumption figures for the PLCs and their extension modules. Verify how many modules the exact 14-point model drives from the current catalog, and add the module currents to the 24 V DC supply budget before ordering.

Which DVP family should I choose for a machine with servo axes?

The SV2. It is the DVP family with integrated motion functions — positioning, speed control and synchronization — and no other slim family is built for that job. Pull the axis count and pulse-channel count for the exact SV2 model from the current catalog, and if the motion outgrows it, the next stop is a dedicated motion controller rather than a bigger PLC.

Do these families share one programming environment?

One operation manual covers the ES2, EX2, SS2, SA2, SX2 and SE models, so the mainstream DVP line shares a single instruction set and programming model — moving a station between those families resizes the hardware but does not retrain the programmer. Take the programming software and the manual from Delta's own download center so the software version matches the firmware you commission.

Are the older SS, SA, SX, SC and SV models still available?

Yes. The current DVP catalog lists the first slim generation — SS, SA, SX, SC and SV — alongside the SS2, SA2, SX2 and SV2, so the older models remain the like-for-like repair path for installed panels. Use them for spares and repairs only: on new machines the second generation is the pick, and on the SS2 the documented gains over the SS are faster execution and enhanced monitoring.

What if the station outgrows every slim family?

Move up, not out. The DVP line continues above the slim families with the EH3 and SE models, and that is where a station with more I/O, memory or networking belongs — not an overloaded slim base with extension modules chained until the enclosure is full. The practical trigger is the module count the chosen base drives, which is a number on the model's catalog line.

Keep reading

  • Selection guide

    Selecting a Mitsubishi MELSEC PLC family for your application

    Start with MELSEC iQ-F for new compact machines and iQ-R for new modular systems. For an installed FX3, L or Q system, match the CPU, I/O and network requirements and check the exact model’s availability and migration path before ordering.

    PLC programming

  • Selection guide

    How to choose an S7 PLC family for a machine

    For a new machine, pick the S7-1200 when the job is standalone control with modest I/O and one or two axes, and the S7-1500 when you need coordinated motion, controller-integrated safety, a fast scan or a large I/O count. Use S7-300 and S7-400 only to extend plants that already run them. Program both current families in TIA Portal.

    PLC programming

  • Selection guide

    Selecting an ABB AC500 PLC family for your application

    Shortlist AC500-eCo for compact machines and modular AC500 where the exact I/O, network or timing limits require it. Check the applicable XC variants for harsh conditions. Select and validate safety hardware against the machine risk assessment.

    PLC programming