Short answer
The Unknown TAP adapter in the WS configuration tool is a Windows driver problem, not a safety-PLC restriction: eCatcher 6.7.8 shipped TAP driver 9.24, which the WS tool cannot classify. Install TAP driver 9.23, reopen the tool, and the adapter becomes selectable for communication with the WS0-CPU320202 over the VPN. eCatcher 6.7.10 reverts to driver 9.21, so read the driver version, not the eCatcher version, when this fault appears.
On this page
The Unknown entry is a Windows TAP driver fault, and the fix is a driver swap. eCatcher 6.7.8 installs TAP driver 9.24; WS configuration tool 1.9.1.279 lists that driver's interface as Unknown and never offers it in the connection list. Installing TAP driver 9.23 in its place turned the same interface into a recognized, selectable adapter, and the tool then communicated with the WS0-CPU320202 safety CPU through the standing VPN tunnel. Nothing on the safety side blocked anything — the tool simply never offered the interface. Read the driver version in the adapter's properties before touching OpenVPN settings or PowerShell.
The Unknown entry is a driver classification, not a safety block #
The WS tool builds its interface list from what Windows reports about each network adapter. With TAP driver 9.24 installed, tool version 1.9.1.279 could not place the eCatcher TAP interface and filed it under Unknown, where it cannot be selected. With driver 9.23 installed on the same PC, the same interface appeared as an ordinary adapter and carried the PLC session. The tunnel was up throughout; only the tool's view of the adapter changed.
Reaching a safety controller from a Windows PC over a routed link is routine — reaching a safety PLC over EtherCAT EoE from a Windows PC is the same class of access — so treat this as a PC-side networking fault, not a safety restriction. The one safety point that matters here: a driver swap on the engineering PC changes nothing in the safety program, and a remote session grants no exemption from the documented change procedure and competence requirements for safety code.
The observations, as reported and confirmed on that installation:
| Component | Version | Result |
|---|---|---|
| WS configuration tool | 1.9.1.279 | TAP interface unavailable while driver 9.24 was installed |
| eCatcher | 6.7.8 | VPN established; its TAP interface not recognized by the WS tool |
| TAP driver | 9.24 | Interface listed as Unknown |
| TAP driver | 9.23 | Interface recognized, selectable, carried PLC communication |
| eCatcher | 6.7.10 | Ships TAP driver 9.21 after the adapter update was reverted |
Replace driver 9.24 with 9.23 #
- Open Windows network connections and find the eCatcher TAP adapter; it carries the name Talk2m-eCatcher.
- Open the adapter's properties and read the driver version shown there. 9.24 is the failing build against WS tool 1.9.1.279.
- Replace the driver with build 9.23 from the eCatcher vendor's own distribution; the vendor supplies TAP driver packages through its support channel. Do not pull a TAP driver from a third-party mirror — the build number is the entire fix, and reposts are not version-controlled.
- Reopen the properties and confirm the driver version now reads 9.23.
- Restart the WS configuration tool and reopen its interface list.
- Select the TAP adapter and connect to the WS0-CPU320202 through the established tunnel.
Do not try to script the adapter out of the Unknown group with PowerShell or OpenVPN configuration edits first. In the documented case the driver version alone decided the outcome, and none of those edits were needed; make them only after the driver reads 9.23 and the interface still misbehaves.
Worked example: WS tool 1.9.1.279 over an eCatcher 6.7.8 tunnel to a WS0-CPU320202 #
Inputs, each from the documented case:
- WS configuration tool 1.9.1.279 on the engineering PC (the thread's installation).
- eCatcher 6.7.8, which installs TAP driver 9.24 alongside it (the vendor reply identifies 9.24 as the build used by eCatcher 6.7.x).
- Remote side: a WS0-CPU320202 safety CPU reached through the Flexy205 router's VPN.
- Symptom: tunnel up, adapter listed as Unknown, nothing selectable in the tool's interface list.
Rule in words: the interface the WS tool can offer follows the installed TAP driver build. The two documented observations pair 9.24 with Unknown and 9.23 with recognized-and-selectable, on the same PC, same tool, same tunnel.
The arithmetic is a build comparison:
- Failing build 9.24, working build 9.23: 9.24 − 9.23 = 0.01 — one build step separates Unknown from usable.
- Build shipped by eCatcher 6.7.10: 9.23 − 9.21 = 0.02 — the version an update installs sits two build steps below the confirmed one.
Result: after the swap to 9.23, the interface left the Unknown group, appeared as a selectable adapter, and the WS tool's communication to the WS0-CPU320202 ran through the standing tunnel.
Decision, by what the properties page reads: 9.24 → replace with 9.23 before any other troubleshooting step. 9.23 → the adapter is not this fault; chase the tunnel or the addressing. 9.21 → test recognition in the WS tool and do not assume it behaves like 9.23.
When a second VPN client shares the PC #
Coexistence is the other documented source of TAP trouble. Reports against eCatcher include a SINEMA RC client and a Sophos VPN breaking the tunnel or the adapter after their installs, because each VPN client wants a TAP interface and they fight over them. The vendor's remedy is renaming so each client keeps its own adapter; eCatcher's is the one named Talk2m-eCatcher, and the vendor publishes the renaming procedure for running other VPN services alongside it. If no TAP adapter appears in network connections at all, that is the separate missing-adapter fault the vendor also documents — repair the eCatcher install rather than swapping drivers. In every case, check the driver version first, because a rename does nothing for a 9.24 build the WS tool cannot classify.
What eCatcher 6.7.10 changes #
The 6.7.10 release reverted the TAP adapter update and ships driver 9.21 again, so updating eCatcher also clears 9.24 from that package. But 9.21 is not the build confirmed against the WS tool — 9.23 is, on eCatcher 6.7.8. After any eCatcher update, read the driver number in the adapter properties again before blaming the tool: if the interface has dropped back to Unknown on 9.21, put 9.23 back from the vendor's package.
Verify the repair end to end #
Confirm all three, in this order:
- The TAP interface no longer sits in the Unknown group in the WS tool's list.
- It is selectable, and the selection holds when the connection dialog reopens.
- An online session to the WS0-CPU320202 completes over the tunnel — discovery alone is not the repair.
If it still fails, record the three versions — WS tool, eCatcher, TAP driver — before going further; that triple identifies the combination, and it is what support asks for first. If the adapter is clean but the safety application itself will not establish its connection, the fault lives a layer above the network: why an FSoE connection is not established on a safety PLC covers that case.
Questions asked
Why does the WS configuration tool show the VPN TAP adapter as Unknown?
Because of the installed TAP driver build, not the safety PLC. In the documented case, WS configuration tool 1.9.1.279 listed the interface as Unknown while TAP driver 9.24, shipped with eCatcher 6.7.x, was installed, and listed it as a normal selectable adapter once driver 9.23 was in place. The VPN tunnel itself was up the whole time; only the tool's view of the interface changed.
Does updating to eCatcher 6.7.10 fix the problem?
It removes driver 9.24 by reverting to TAP driver 9.21, but 9.21 was not the build confirmed against the WS tool; 9.23 was. After updating to 6.7.10, open the WS tool and test adapter recognition and PLC communication. If the interface has dropped back to Unknown on 9.21, install 9.23 again from the vendor's own package.
Is the Unknown adapter a sign the safety PLC refuses VPN connections?
No. Once the driver was corrected, the WS tool communicated with the WS0-CPU320202 through the tunnel with no change on the safety side, and the session behaved like a local one. The fault sat entirely in the Windows driver layer. A remote session does confer one thing to respect: the same documented change procedure and competence requirements for safety code apply as on a direct cable.
Another VPN client is installed on the same PC. Does that matter?
Yes, it is the second documented source of TAP trouble. Coexistence cases reported against eCatcher include a SINEMA RC client and a Sophos VPN breaking the adapter or tunnel after their installs. The vendor's remedy is renaming so each client keeps its own adapter; eCatcher's carries the name Talk2m-eCatcher, so look for that name before you suspect the driver.