Selection guide
Choosing a PLC ladder logic simulator for practice
Short answer
Choose the vendor's own simulator when you must practice that PLC's workflow; otherwise a CODESYS-based soft PLC gives generic IEC 61131-3 practice. An unlicensed CODESYS runtime exits after 2 hours, and TwinCAT 3 needs Windows 10 or 11 and at least 4 GB RAM, so pick by target platform, not by a 'best' label.
On this page
Pick the simulator by target, not by a "best" label. If your goal is one vendor's project workflow, install that vendor's own programming environment and simulator; if your goal is standard ladder practice, install a CODESYS-based soft PLC such as CODESYS Control Win or TwinCAT 3, which runs ladder logic on your PC as a software-based controller. Either way, treat the result as practice: a passing simulation proves the logic under the simulator's conditions, not behaviour on the real PLC.
Decision by learning goal #
| Your goal | Choose | Why |
|---|---|---|
| Practice one vendor's workflow (project tree, its instructions, its HMI tags) | That vendor's environment and simulator | Only it reproduces the vendor's instruction set and project structure |
| Learn standard ladder, timers, counters, scan-based logic | CODESYS-based soft PLC or TwinCAT 3 | Both run IEC 61131-3 ladder on a PC runtime |
| Run logic for more than a session at a time | Licensed runtime | An unlicensed CODESYS SoftPLC runs in demo mode and exits automatically after 2 hours of runtime |
TwinCAT 3 takes more PC: the documented system requirements are a 1.8 GHz or faster processor (dual-core recommended), at least 4 GB RAM, and 16 GB RAM recommended with the engineering shell. The documented supported operating systems are Windows 10 and Windows 11. On a weak laptop, a lighter CODESYS Control runtime is the safer choice; on a capable Windows PC, TwinCAT gives you a full soft PLC free of the 2-hour demo cutoff for practice sessions.
What the CODESYS demo mode means for practice #
Without a valid license the SoftPLC runs in demo mode and exits automatically after 2 hours of runtime, per the CODESYS Store's licensing explanation. For ladder practice that limit is harmless: save the project, restart the runtime, download again. For 24/7 operation you need a license that fits the application. A demo license, once purchased and activated, enables demo mode for 30 days free of charge. The two-hour exit is also the symptom to recognise when a licensed runtime falls back to demo mode: if a runtime with a USB dongle starts stopping after 2 hours, the log files show it defaulted to DEMO mode because the license was not detected — check the dongle and license activation, not your ladder logic.
What "standard ladder" does and does not buy you #
Staying with standard IEC 61131-3 instructions (contacts, coils, TON, CTU, comparison, arithmetic, edge detection) keeps your practice portable, because many vendors' ladder editors share that core. It does not make controllers interchangeable: project structure, instruction variants, data-type handling and runtime scan details still differ by vendor, and several major vendors do not use a CODESYS-based platform at all. So a rung that passes in your simulator is validated for that simulator only.
Install and prove the simulator in one short project #
- Confirm the release's documented requirements: operating system, RAM, runtime package, and the target device the project is compiled for. Record the version and target in your notes so later results stay tied to the environment that produced them.
- Create a minimal ladder project: one input condition driving one output coil. Download it to the PC runtime and go to Run.
- Force or toggle the input online and watch the rung and coil state change as expected.
- Add the instructions your real exercises use — a TON, a counter, an edge trigger — and confirm each behaves as the target PLC's documentation says it should.
- Save the project with its version and target noted. If your intended target differs from the simulator target, label the project practice-only until it runs in the target vendor's environment.
If you are learning from scratch, pair the simulator with a structured set of exercises; our ladder logic practice projects in STEP 7 article shows the kind of rungs to build, and which IEC 61131-3 language fits a cyclic machine controller explains why ladder suits sequential interlock practice.
What a passing run verifies #
A simulation run verifies the logic under the simulator's configured conditions and nothing else: not field wiring, not real I/O addressing on the target module, not scan timing on the target CPU, not vendor-specific instructions. One safety note: never download practice logic to a machine that will run — simulation is where mistakes belong.
The decision #
- Vendor-specific workflow needed: use that vendor's environment and simulator. No substitute reproduces it.
- Generic ladder skills: TwinCAT 3 on a Windows 10 or 11 PC with at least 4 GB RAM (16 GB recommended), or a CODESYS soft PLC on a lighter machine, restarting around the 2-hour demo exit.
- Browser-based simulator required: neither TwinCAT nor a CODESYS soft PLC is confirmed as an online tool; both install locally, so relax that requirement or accept an unidentified browser tool with unverified instruction behaviour.
- Any simulation result: practice evidence only, until the same logic passes in the target controller's environment.
Questions asked
What does a passing simulation not verify?
It verifies only the logic under the simulator's configured conditions: not field wiring, real I/O modules, scan timing on the target controller, or compatibility with another vendor's instruction set and data types. Those need the actual target environment or hardware.
Can a CODESYS soft PLC run unattended without a license?
No. Without a valid license it runs in demo mode and exits automatically, so unattended or 24/7 operation needs a license that fits the application.
Which Windows versions does TwinCAT 3 engineering support?
Older 32-bit systems mentioned in passing elsewhere are not a current compatibility matrix; use the release-specific documentation for the version you install.
Is a simulator run evidence the program will behave the same on my work PLC?
No. Ladder editors, instruction sets, data representation and runtime scan behavior differ by vendor. Mark practice projects as practice-only until they are loaded and tested in the target controller's own programming environment.